|
|
|
商品の詳細:
お支払配送条件:
|
| 電源: | DC12~30V(2線式) | 周囲温度: | -40°C〜80°C(-40°F〜176°F) |
|---|---|---|---|
| 電気定格: | 汎用、防爆、本質安全防爆(認定に応じて) | 認証: | 標準モデルには、ATEX、IECEx、SIL 2 が含まれます (特定の定格についてはマニュアルを参照してください) |
| ハイライト: | MTL dual fieldbus power supply,500mA DIN rail power supply,ATEX IECEx safety barrier |
||
MTL 4646Y Dual Fieldbus Power Supply | 2x 500mA, IS, Diagnostics, DIN Rail, ATEX/IECEx Specs
MTL 4646Y dual-channel fieldbus power supply specifications. Two independent H1/PA segments, 500mA each, advanced diagnostics, 24V DC. ATEX/IECEx approved for hazardous areas.
The MTL 4646Y is a dual-channel advanced fieldbus power supply from MTL's 4600 series, designed to provide regulated power, signal conditioning, and comprehensive diagnostics for two independent FOUNDATION Fieldbus H1 or PROFIBUS PA segments. Each channel delivers a high 500 mA of fieldbus power, features integrated diagnostics (indicated by the "Y" suffix), provides short-circuit and overload protection, and carries ATEX and IECEx approvals for Zone 1 hazardous area installations. The 4646Y is a high-capacity, intelligent solution for demanding fieldbus networks requiring robust power and monitoring.
|
Parameter |
Specification |
|---|---|
|
Model Number |
4646Y |
|
Product Series |
MTL 4600 Series |
|
Product Type |
Advanced Dual-Channel Fieldbus Power Supply with Diagnostics and Intrinsic Safety |
|
Safety Standard |
Intrinsic Safety (IS) |
|
Approvals |
ATEX, IECEx (see specific certifications) |
|
Hazardous Area Rating |
Zone 1, IIC, T6 (Gas), A21, T85°C (Dust) |
|
Network Type |
FOUNDATION Fieldbus H1, PROFIBUS PA |
|
Power Specifications |
|
|
Input Voltage |
20-30V DC (typically 24V DC) |
|
Input Current |
2.0A maximum (both channels) |
|
Input Power |
50W maximum |
|
Output Voltage (per channel) |
20-24V DC (regulated) |
|
Output Current (per channel) |
500 mA (maximum continuous, per channel) |
|
Total Output Current (combined) |
800 mA (maximum shared between channels) |
|
Current Limiting |
Electronic, per channel, adjustable |
|
Short Circuit Protection |
Yes, per channel, with auto-recovery and logging |
|
Overload Protection |
Yes, with configurable thresholds |
|
Diagnostic Features |
|
|
Segment Monitoring (per channel) |
Real-time voltage, current, power, temperature |
|
Advanced Diagnostics |
Cable fault detection, device count estimation, communication health |
|
Status Indication |
Multi-color LED per channel with diagnostic patterns |
|
Communication Interface |
RS-485 (Modbus RTU) for configuration and remote diagnostics |
|
Event Logging |
Configurable alarm and event recording with time-stamp |
|
Communications Specifications |
|
|
Signal Conditioning |
Built-in, per channel, ensures communication integrity |
|
Termination |
Built-in 100 Ω termination per channel (software configurable) |
|
Baud Rate |
31.25 kbps (Fieldbus H1, PROFIBUS PA) |
|
Channel Isolation |
Channels are isolated from each other |
|
General Specifications |
|
|
Operating Temperature |
-20°C to +60°C (-4°F to +140°F) |
|
Storage Temperature |
-40°C to +85°C (-40°F to 185°F) |
|
Relative Humidity |
0-95% non-condensing |
|
Connection Type |
Screw terminals |
|
Wire Size |
0.2-2.5 mm² (24-12 AWG) |
|
Mounting |
DIN rail 35mm |
|
Degree of Protection |
IP20 (requires enclosure) |
|
Dimensions (W × H × D) |
70.0 × 124 × 115 mm |
|
Weight |
Approx. 900 g |
|
Housing Material |
Polycarbonate/PBT |
|
LED Indicators |
Per channel: Multi-color status LED (Green/Yellow/Red) |
|
Configuration |
Software configurable via RS-485 interface |
|
Certifications |
ATEX, IECEx, FM, CSA, DNV GL, Marine, SIL 2 capable, CE, RoHS |
Note: Specifications are based on MTL 4600 series documentation. The "Y" suffix indicates a specific feature set, typically including enhanced diagnostics. Always verify with the latest product datasheet.
High Current Capacity: 500 mA per channel for power-intensive segments
Dual Independent Channels: Two completely isolated segments in one unit
Advanced Diagnostics: Comprehensive real-time monitoring and fault detection
RS-485 Interface: Remote configuration and diagnostic access via Modbus RTU
Configurable Parameters: Current limits, alarm thresholds, termination set via software
Intrinsic Safety: Approved for Zone 1 hazardous locations
Event Logging: Stores diagnostic events for troubleshooting and predictive maintenance
Multi-color Status LEDs: Detailed visual indication of each channel's health
Global Approvals: Certified for international hazardous area applications
SIL 2 Capable: Suitable for safety instrumented systems when properly configured
|
Parameter |
Minimum |
Typical |
Maximum |
Unit |
|---|---|---|---|---|
|
Input Voltage |
20 |
24 |
30 |
V DC |
|
Output Voltage |
20 |
22 |
24 |
V DC |
|
Output Current (per channel) |
0 |
- |
500 |
mA |
|
Total Output Current (combined) |
- |
- |
800 |
mA |
|
Current Limit Settings |
Configurable from 100 to 500 mA |
- |
- |
- |
|
Ripple and Noise |
- |
50 |
100 |
mV p-p |
|
Load Regulation |
- |
±0.5% |
±1% |
of Vout |
|
Response Time |
- |
< 50 |
100 |
µs |
|
Channel-to-Channel Isolation |
500 |
- |
- |
V AC |
|
Parameter |
Monitoring Capability |
Diagnostic Value |
|---|---|---|
|
Segment Voltage |
Real-time measurement |
Wiring integrity, voltage drop |
|
Segment Current |
Real-time measurement |
Load monitoring, overload prediction |
|
Power Consumption |
Calculated real-time |
Segment power budget |
|
Estimated Device Count |
Calculated from current |
Device presence/removal detection |
|
Communication Health |
Signal quality analysis |
Network integrity assessment |
|
Internal Temperature |
Sensor measurement |
Thermal management and derating |
|
Cable Diagnostics |
Advanced algorithms |
Short circuit, open circuit detection |
|
LED Color |
Pattern |
Meaning |
|---|---|---|
|
Green |
Solid |
Normal operation, segment healthy |
|
Green |
Flashing (1 Hz) |
Communications activity detected |
|
Yellow |
Solid |
Warning condition (e.g., >80% current limit) |
|
Yellow |
Flashing (1 Hz) |
Configuration mode active |
|
Red |
Solid |
Fault condition (short circuit, overload) |
|
Red |
Flashing (2 Hz) |
Communication fault |
|
Red |
Flashing (4 Hz) |
Over-temperature warning |
|
Off |
- |
No power or channel disabled |
|
Parameter |
Symbol |
Value |
Unit |
|---|---|---|---|
|
Maximum Output Voltage (Uo) |
Uo |
24 |
V |
|
Maximum Output Current (Io) |
Io |
500 |
mA |
|
Maximum Output Power (Po) |
Po |
12.0 |
W |
|
Maximum External Capacitance (Co) |
Co |
According to connected apparatus |
nF |
|
Maximum External Inductance (Lo) |
Lo |
According to connected apparatus |
mH |
Note: The 4646Y is an associated apparatus. All connected fieldbus devices must be intrinsically safe certified. The 800mA shared limit must be considered in system design.
|
Configuration |
Channel 1 Load |
Channel 2 Load |
Total Load |
Status |
|---|---|---|---|---|
|
Balanced |
400 mA |
400 mA |
800 mA |
✅ Acceptable |
|
Unbalanced |
500 mA |
300 mA |
800 mA |
✅ Acceptable |
|
Overload |
500 mA |
500 mA |
1000 mA |
❌ Exceeds 800mA limit |
|
Typical Design |
350 mA |
350 mA |
700 mA |
✅ With 100mA margin |
Critical: The total combined output for both channels must not exceed 800mA.
High-Demand Process Units: Segments with many devices or high-power instruments
Critical Control Loops: Safety and environmental monitoring systems
Predictive Maintenance Programs: Facilities using diagnostic data for analytics
Remote Monitoring Sites: Offshore platforms or unmanned facilities
SIL 2 Applications: Safety instrumented systems requiring diagnostics
Large Tank Farms: Multiple high-density measurement segments
Power Generation: Critical boiler and turbine control networks
Any application requiring two high-current fieldbus segments with advanced health monitoring
Shared Current Limit: The 800mA total output is a critical design parameter. The sum of both channel loads must be ≤ 800mA.
Power Supply Requirements: Requires a robust 20-30V DC input. Recommended: 24V DC, 3A capacity minimum.
Configuration Software: Initial setup requires configuration software (via RS-485) for current limits, termination, and alarm setpoints.
Thermal Management: High current capacity requires excellent ventilation. Do not install in confined spaces or exceed ambient temperature limits.
Diagnostic Utilization: Implement alarms for warning conditions (yellow LED) to enable proactive maintenance before faults occur.
Certification Compliance: Verify that the 4646Y's specific certifications match the hazardous area classification (Zone 1, IIC, T6).
Grounding and Shielding: Follow manufacturer's instructions precisely for fieldbus shield grounding to ensure communication integrity.
SIL Applications: For SIL 2 use, follow all manufacturer guidelines for configuration, proof testing, and diagnostic coverage.
Event Log Review: Periodically review the event log via the RS-485 interface to identify trends or recurring issues.
Pre-Commissioning Check: Before connecting field devices, configure each channel's current limit appropriately and verify termination settings.
Note: This data sheet provides general specifications for the MTL 4646Y advanced dual-channel fieldbus power supply. For complete installation guidelines, configuration software manual, Modbus register map, diagnostic interpretation, and safety instructions, consult the official MTL 4600 Series Technical Manual and 4646Y Configuration Guide. Always verify that the product configuration matches your application requirements and strictly adhere to the 800mA total current limit.
Founded in 2012, ACH is a top-tier distributor of industrial automation products, supplying genuine devices from leading brands like ABB, P+F, E&H, AB, MTL and EMERSON to emerging markets worldwide. Our mission is to provide 100% Genuine products at the most competitive prices, helping customers reduce costs and strengthen their market position.
Long-term brand partners can get competitive product prices. At the same time, ACH controls the profit per order to 5%, providing the most competitive prices.
Yes, all products from ACH are certified genuine OEM units. We acquire our inventory through official OEM channels and trusted third-party suppliers, ensuring every item is authentic and reliable.
We'll handle the shipping for you. Through our partnerships, we can secure competitive rates with major carriers like FedEx, DHL, TNT, and UPS, ensuring a smooth and cost-effective delivery.
One-year Warranty.
Products are divided into spot and futures, and the delivery period of different brands of products is also different. For details, please contact the ACH business manager.
コンタクトパーソン: sales2