MTL HCU16 HART Communication Unit | 16-Ch, IS, Modbus RTU, DIN Rail, ATEX Specs
MTL HCU16 HART communication unit specifications. 16-channel, 4-20mA+HART, intrinsic safety, Modbus RTU, DIN rail. ATEX/IECEx approved for hazardous area networks.
The MTL HCU16 is a 16-channel HART communication unit designed to interface 4-20mA+HART signals from hazardous areas to a Modbus RTU network via RS-485. This unit provides intrinsic safety protection for sixteen HART field instrument channels, enables digital communication with HART devices while maintaining analog 4-20mA signaling, and carries ATEX and IECEx approvals for Zone 1 hazardous locations. The "HCU16" designation indicates a 16-channel HART communication unit. This device provides a high-density solution for integrating large numbers of HART field instruments into modern control and asset management systems.
|
Parameter |
Specification |
|---|---|
|
Model Number |
HCU16 |
|
Product Series |
MTL HCU Series |
|
Product Type |
16-Channel HART Communication Unit with Intrinsic Safety |
|
Safety Standard |
Intrinsic Safety (IS) |
|
Approvals |
ATEX, IECEx, FM (see specific certifications) |
|
Hazardous Area Rating |
Zone 1, IIC, T6 (Gas), A21, T85°C (Dust) |
|
Channel Count |
16 channels (grouped isolation) |
|
Channel Type |
4-20mA analog with HART digital communication |
|
Analog Specifications |
|
|
Input Signal |
4-20mA DC, 2-wire |
|
Input Impedance |
50 Ω |
|
Accuracy |
±0.05% of span (analog measurement) |
|
Update Rate |
1 second for all 16 channels (typical) |
|
Digital Specifications |
|
|
HART Protocol |
HART 5, 6, 7 compatible (Bell 202 FSK) |
|
HART Communication |
Point-to-point mode |
|
HART Variables |
PV, SV, TV, QV (4 process variables) plus device status |
|
Communications Interface |
|
|
Host Interface |
RS-485, 2-wire, half-duplex |
|
Protocol |
Modbus RTU |
|
Baud Rate |
9600 to 115200 bps (configurable) |
|
Address Range |
1-247 (Modbus RTU address) |
|
Isolation |
500V AC (field to RS-485, between channel groups) |
|
General Specifications |
|
|
Power Supply |
20-30V DC (typically 24V DC) |
|
Power Consumption |
8W typical, 12W maximum |
|
Operating Temperature |
-20°C to +60°C (-4°F to +140°F) |
|
Storage Temperature |
-40°C to +85°C (-40°F to +185°F) |
|
Relative Humidity |
0-95% non-condensing |
|
Connection Type |
Screw terminals (field and RS-485) |
|
Wire Size |
0.2-2.5 mm² (24-12 AWG) |
|
Mounting |
DIN rail 35mm |
|
Degree of Protection |
IP20 (requires enclosure) |
|
Dimensions (W × H × D) |
140 × 124 × 115 mm (approx. 8 modules wide) |
|
Weight |
Approx. 600 g |
|
Housing Material |
Polycarbonate/PBT |
|
LED Indicators |
Power, Communication, Channel group status |
|
Configuration |
Software via Modbus or dedicated configurator |
|
Certifications |
ATEX, IECEx, FM, CSA, SIL 2 capable |
Note: Specifications are based on MTL HCU series documentation. The HCU16 provides 16 channels in a single unit with grouped isolation. Always verify with the latest product datasheet.
High Channel Density: 16 HART channels in a single, compact unit
Modbus RTU Interface: Industry-standard RS-485 Modbus protocol for easy integration
Full HART Support: HART 5, 6, and 7 compatibility for modern field instruments
Intrinsic Safety: Approved for Zone 1 hazardous locations
Group Isolation: Channels are isolated in groups (typically 4 or 8 channels per group)
High Accuracy: ±0.05% accuracy for precise analog measurement
Fast Update Rate: 1 second update for all 16 channels
Configurable Addressing: Modbus RTU address 1-247 for network flexibility
Global Approvals: Certified for international hazardous area applications
SIL 2 Capable: Suitable for safety applications when properly configured
|
Feature |
Specification |
|---|---|
|
Protocol Support |
HART 5, 6, 7 |
|
Communication Mode |
Point-to-point (primary) |
|
Variables Available |
PV, SV, TV, QV + device variables |
|
Update Method |
Polled by host via Modbus |
|
Command Support |
Universal and Common Practice commands |
|
Device Specific Commands |
Supported through pass-through function |
|
Data Type |
Register Range |
Description |
|---|---|---|
|
Analog Inputs |
30001-30016 |
Channel 1-16 analog values (4-20mA) |
|
HART PV |
30017-30032 |
Channel 1-16 HART primary variable |
|
HART SV |
30033-30048 |
Channel 1-16 HART secondary variable |
|
HART TV |
30049-30064 |
Channel 1-16 HART tertiary variable |
|
HART QV |
30065-30080 |
Channel 1-16 HART quaternary variable |
|
Status Registers |
30101-30116 |
Device status and diagnostics per channel |
|
Configuration |
40001-400xx |
Device configuration parameters |
|
Parameter |
Symbol |
Typical Value |
Unit |
|---|---|---|---|
|
Maximum Input Voltage (Ui) |
Ui |
30 |
V |
|
Maximum Input Current (Ii) |
Ii |
30 |
mA per channel |
|
Maximum External Capacitance (Co) |
Co |
According to connected device |
nF |
|
Maximum External Inductance (Lo) |
Lo |
According to connected device |
mH |
Note: The HCU16 is an associated apparatus. All connected HART devices in the hazardous area must be certified as intrinsically safe and their entity parameters must be considered in the loop design.
[Control System/SCADA]
|
[Modbus RTU Network - RS-485]
|
[MTL HCU16 - 16 Channels]
| | | ... |
Chan1 Chan2 Chan3 ... Chan16
| | | ... |
[HART Transmitters in Hazardous Area]
Large Process Units: Multiple measurement points in distillation columns, reactors, or large vessels
Tank Farms: High-density level and temperature monitoring for storage tanks
Compressor Stations: Multiple pressure, temperature, and vibration monitoring points
Pipeline Stations: Multiple measurement points along pipelines
Power Generation: Extensive temperature and pressure monitoring in power plants
Water Treatment Plants: Multiple measurement points in large treatment facilities
Any application requiring high-density HART communication from Zone 1 hazardous areas
HART Device Compatibility: All connected HART field devices must be certified for use in the hazardous area and compatible with the HCU16's entity parameters.
Power Supply Sizing: The 24V DC power supply must provide sufficient current for the HCU16 plus all connected field devices. Calculate: HCU16 (0.5A) + Σ(Field device currents).
RS-485 Network Design: Requires proper termination (120Ω at both ends), correct polarity, and consideration of network length vs. baud rate. Maximum devices on the network: 32.
Grounding and Isolation: Follow manufacturer's grounding instructions carefully. The HCU16 provides galvanic isolation between field and system sides.
Configuration Requirements: The unit requires configuration for baud rate, parity, Modbus address, and HART parameters before use. This is typically done via configuration software.
Update Rate Consideration: With 16 channels, the total polling time depends on baud rate and host polling strategy. At 9600 baud, allow 2-3 seconds for complete update of all channels.
Channel Grouping: Channels are isolated in groups, not individually. Consider this when mixing different types of field devices or in fault scenarios.
Certification Compliance: Verify that the HCU16's specific certifications (ATEX, IECEx, etc.) match the hazardous area classification of your installation site.
Diagnostic Monitoring: Monitor device status registers for early detection of field device issues, communication errors, or configuration problems.
Physical Installation: The HCU16 is relatively wide (140mm). Ensure adequate space in the control panel and proper ventilation, especially when operating at high ambient temperatures.
Note: This data sheet provides general specifications for the MTL HCU16 HART communication unit. For complete installation guidelines, detailed Modbus register maps, configuration procedures, and safety instructions, consult the official MTL HCU Series Technical Manual and HCU16 Configuration Guide. Always verify that the product configuration and certifications match your specific application requirements. HART® is a registered trademark of the FieldComm Group.
Founded in 2012, ACH is a top-tier distributor of industrial automation products, supplying genuine devices from leading brands like ABB, P+F, E&H, AB, MTL and EMERSON to emerging markets worldwide. Our mission is to provide 100% Genuine products at the most competitive prices, helping customers reduce costs and strengthen their market position.
Long-term brand partners can get competitive product prices. At the same time, ACH controls the profit per order to 5%, providing the most competitive prices.
Yes, all products from ACH are certified genuine OEM units. We acquire our inventory through official OEM channels and trusted third-party suppliers, ensuring every item is authentic and reliable.
We'll handle the shipping for you. Through our partnerships, we can secure competitive rates with major carriers like FedEx, DHL, TNT, and UPS, ensuring a smooth and cost-effective delivery.
One-year Warranty.
Products are divided into spot and futures, and the delivery period of different brands of products is also different. For details, please contact the ACH business manager.
Pessoa de Contato: sales2