logo
100% genuine products & Actual product photos
Home
Products
Videos
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
News
Home ProductsMTL Safety Barrier

MTL 5516C HART Isolator | 4-20mA+HART, Loop Power, IS, DIN Rail, ATEX/FM/CSA

I'm Online Chat Now
Certification
china Achievers Automation Limited certification
china Achievers Automation Limited certification
"ACH has proven to be a reliable partner. Their products are genuine and high-quality, with competitive prices and on-time delivery. We trust them as our long-term supplier in automation."

—— Mohammed Al-Farsi, Procurement

"For us, cost efficiency and authenticity are key. ACH helps reduce expenses while ensuring reliable quality and timely supply, making them a strong partner in our operations."

—— Procurement Manager

"For us, cost efficiency and authenticity are key. ACH helps reduce expenses while ensuring reliable quality and timely supply, making them a strong partner in our operations."

—— Supply Chain Director

"ACH offers quick response, flexible solutions, and fair pricing. The products are always genuine and reliable, and their friendly support makes cooperation smooth."

—— Operations Manager

"ACH provides genuine products with stable quality and fair pricing. Their fast response and reliable delivery give us confidence to continue working with them."

—— Engineering Manager

"We value ACH for their consistent quality and competitive pricing. Deliveries are always reliable, and their professional support makes procurement much easier for our team."

—— Procurement Head

MTL 5516C HART Isolator | 4-20mA+HART, Loop Power, IS, DIN Rail, ATEX/FM/CSA

MTL 5516C HART Isolator | 4-20mA+HART, Loop Power, IS, DIN Rail, ATEX/FM/CSA

Large Image :  MTL 5516C HART Isolator | 4-20mA+HART, Loop Power, IS, DIN Rail, ATEX/FM/CSA Get Best Price

Product Details:
Place of Origin: GB
Brand Name: MTL
Certification: ATEX
Model Number: 5516C
Document: ACH-AB-P+F-E+H-IFM-ASCO-YOK...WA.pdf
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: carton
Delivery Time: Negotiable
Payment Terms: T/T,XT,ALIPAY
Supply Ability: 100pcs per month
Detailed Product Description
Power Supply: 12-30 V DC (Two-wire) Ambient Temperature: -40°C To 80°C (-40°F To 176°F)
Electrical Rating: General Purpose, Explosion-proof, Intrinsic Safety (depends On Certification) Certifications: Standard Models Include ATEX, IECEx, SIL 2 (consult Manual For Specific Ratings)
Highlight:

MTL 5516C HART isolator DIN rail

,

HART isolator 4-20mA loop power

,

ATEX FM CSA safety barrier

MTL 5516C HART Isolator | 4-20mA+HART, Loop Power, IS, DIN Rail, ATEX/FM/CSA

MTL 5516C HART isolator specifications. Provides 4-20mA+HART signal isolation and 24V loop power. Dual-channel, 24V DC, for hazardous area smart transmitters.

Product Overview

The MTL 5516C is a dual-channel HART analog isolator that provides both intrinsic safety (IS) isolation and loop power for 2-wire HART field transmitters. It accepts a 4-20mA signal with HART digital communication from a smart transmitter in the hazardous area, provides IS isolation and conditioning, and delivers a replicated, isolated 4-20mA+HART output to the safe area, while also powering the transmitter loop.

Technical Specifications

Parameter

Specification

Manufacturer

MTL (MTL Instruments Group)

Model

5516C

Product Type

Dual-Channel HART Isolator with Loop Power

Hazardous Area Rating

Zone 1, IIC, T6 (Gas), A21, T85°C (Dust)

Key Certifications

ATEX, IECEx, FM, CSA, NEPSI

Input Signal

4-20mA with HART FSK signal (from field device)

Output Signal

4-20mA with HART FSK signal (to safe area)

Loop Power Output

24V DC (for 2-wire HART transmitter)

Analog Accuracy

±0.05% of span

HART Support

Yes, Bell 202, bidirectional

Isolation Rating

500V AC (Field to System, Channel to Channel)

Power Supply

20-30V DC (24V typical) for isolator electronics

Operating Temperature

-20°C to +60°C

Mounting

DIN Rail 35mm

Dimensions (WxHxD)

12.5 x 100 x 115 mm

Configuration

Via PC software (USB cable required)

LED Indicators

2 x Bi-color (Power/Status, HART Activity)

Key Features

  • Integrated Loop Power:​ Supplies 24V DC to power 2-wire HART transmitters in hazardous areas

  • HART Protocol Support:​ Full bidirectional HART communication (Bell 202 standard)

  • Dual Independent Channels:​ Two fully isolated HART channels with individual loop power

  • High Accuracy:​ ±0.05% analog signal accuracy

  • Intrinsic Safety:​ Certified for Zone 1/21 hazardous locations

  • Complete Isolation:​ 500V isolation prevents ground loops and protects systems

  • Transparent Operation:​ Passes HART data unchanged; no addressing needed on the isolator

  • Software Configurable:​ Set fail-safe modes, damping, and alarm parameters via PC

  • Visual Diagnostics:​ Per-channel LEDs indicate power and HART communication activity

  • Reduced Wiring:​ Eliminates need for separate IS power supply for each transmitter

Applications

  • Powering and isolating 2-wire HART transmitters in hazardous areas

  • Smart pressure, temperature, and level transmitter installations

  • HART device integration with DCS/PLC systems requiring isolation

  • Asset management systems with HART device monitoring

  • Safety instrumented systems (SIL 2 capable) with HART communication

Important Notes

  1. The 5516C provides loop power to the field transmitter, eliminating the need for a separate IS power supply

  2. Verify the total loop resistance (transmitter + wiring) is within the isolator's compliance voltage

  3. Configuration is required via MTL software for proper operation

  4. Each channel provides independent isolation and loop power

  5. Use single twisted-pair cable for HART communication, separate from power lines

MTL 5516C HART Isolator | 4-20mA+HART, Loop Power, IS, DIN Rail, ATEX/FM/CSA 0

About ACH

Founded in 2012, ACH is a top-tier distributor of industrial automation products, supplying genuine devices from leading brands like ABB, P+F, E&H, AB, MTL and EMERSON to emerging markets worldwide. Our mission is to provide 100% Genuine products at the most competitive prices, helping customers reduce costs and strengthen their market position.

MTL 5516C HART Isolator | 4-20mA+HART, Loop Power, IS, DIN Rail, ATEX/FM/CSA 1
Frequently Ask & Questions
Are preferential prices available?

Long-term brand partners can get competitive product prices. At the same time, ACH controls the profit per order to 5%, providing the most competitive prices.

Are the Products Genuine OEM Units?

Yes, all products from ACH are certified genuine OEM units. We acquire our inventory through official OEM channels and trusted third-party suppliers, ensuring every item is authentic and reliable.

How will you arrange shipment?

We'll handle the shipping for you. Through our partnerships, we can secure competitive rates with major carriers like FedEx, DHL, TNT, and UPS, ensuring a smooth and cost-effective delivery.

What is the warranty of goods?

One-year Warranty.

How long is the logistics cycle of the product?

Products are divided into spot and futures, and the delivery period of different brands of products is also different. For details, please contact the ACH business manager.

Contact Details
Achievers Automation Limited

Contact Person: sales2

Send your inquiry directly to us