logo
100% genuine products & Actual product photos
Home
Products
Videos
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
News
Home ProductsMTL Safety Barrier

MTL 5049 Active Isolator | Loop-Powered, 4-20mA in/out, IS, DIN Rail, ATEX/IECEx/FM

I'm Online Chat Now
Certification
china Achievers Automation Limited certification
china Achievers Automation Limited certification
"ACH has proven to be a reliable partner. Their products are genuine and high-quality, with competitive prices and on-time delivery. We trust them as our long-term supplier in automation."

—— Mohammed Al-Farsi, Procurement

"For us, cost efficiency and authenticity are key. ACH helps reduce expenses while ensuring reliable quality and timely supply, making them a strong partner in our operations."

—— Procurement Manager

"For us, cost efficiency and authenticity are key. ACH helps reduce expenses while ensuring reliable quality and timely supply, making them a strong partner in our operations."

—— Supply Chain Director

"ACH offers quick response, flexible solutions, and fair pricing. The products are always genuine and reliable, and their friendly support makes cooperation smooth."

—— Operations Manager

"ACH provides genuine products with stable quality and fair pricing. Their fast response and reliable delivery give us confidence to continue working with them."

—— Engineering Manager

"We value ACH for their consistent quality and competitive pricing. Deliveries are always reliable, and their professional support makes procurement much easier for our team."

—— Procurement Head

MTL 5049 Active Isolator | Loop-Powered, 4-20mA in/out, IS, DIN Rail, ATEX/IECEx/FM

MTL 5049 Active Isolator | Loop-Powered, 4-20mA in/out, IS, DIN Rail, ATEX/IECEx/FM
MTL 5049 Active Isolator | Loop-Powered, 4-20mA in/out, IS, DIN Rail, ATEX/IECEx/FM MTL 5049 Active Isolator | Loop-Powered, 4-20mA in/out, IS, DIN Rail, ATEX/IECEx/FM MTL 5049 Active Isolator | Loop-Powered, 4-20mA in/out, IS, DIN Rail, ATEX/IECEx/FM

Large Image :  MTL 5049 Active Isolator | Loop-Powered, 4-20mA in/out, IS, DIN Rail, ATEX/IECEx/FM Get Best Price

Product Details:
Place of Origin: GB
Brand Name: MTL
Certification: ATEX
Model Number: 5049
Document: ACH-AB-P+F-E+H-IFM-ASCO-YOK...WA.pdf
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: carton
Delivery Time: Negotiable
Payment Terms: T/T,XT,ALIPAY
Supply Ability: 100pcs per month
Detailed Product Description
Power Supply: 12-30 V DC (Two-wire) Ambient Temperature: -40°C To 80°C (-40°F To 176°F)
Electrical Rating: General Purpose, Explosion-proof, Intrinsic Safety (depends On Certification) Certifications: Standard Models Include ATEX, IECEx, SIL 2 (consult Manual For Specific Ratings)
Highlight:

MTL 5049 loop-powered isolator

,

4-20mA active isolator DIN rail

,

ATEX IECEx FM safety barrier

MTL 5049 Active Isolator | Loop-Powered, 4-20mA in/out, IS, DIN Rail, ATEX/IECEx/FM

MTL 5049 active isolator specifications. Loop-powered, 2-wire, 4-20mA input, 4-20mA output, intrinsic safety, 24V DC. ATEX/IECEx/FM approved for hazardous areas.


Product Overview

The MTL 5049​ is a single-channel, loop-powered (2-wire) isolator and repeater​ from MTL's 5000 series. It is designed to be inserted directly into a standard 4-20mA current loop. The device is powered entirely by the loop current​ itself, requiring no separate power supply. It accepts a 4-20mA input signal​ from a hazardous area transmitter, provides intrinsic safety (IS) isolation, signal conditioning, and boosting, and delivers a regenerated, isolated 4-20mA output​ to the safe-area control system. Its loop-powered design simplifies installation and saves wiring costs.

Technical Specifications

Parameter

Specification

Model Number

5049

Product Series

MTL 5000 Series

Product Type

Loop-Powered (2-Wire) Current Isolator/Repeater

Safety Standard

Intrinsic Safety (IS)

Approvals

ATEX, IECEx, FM, CSA, NEPSI, etc.

Hazardous Area Rating

Zone 1, IIC, T6 (Gas), A21, T85°C (Dust)

Input Specifications


Input Signal

4-20mA DC (2-wire, loop-powered)

Input Impedance

Very Low (typically < 2 Ω) - adds negligible voltage drop.

Input Compliance Voltage

Requires a minimum voltage drop to operate (see General Specs).

Input Accuracy

±0.1% of span (typical, at 23°C)

Output Specifications


Output Signal

4-20mA DC, 2-wire, isolated, active sourcing output.

Output Load

0-600 Ω (maximum, dependent on available loop voltage).

Output Accuracy

±0.1% of span

Temperature Coefficient

< ±0.01% of span / °C

Output Noise

< 10 µA p-p (typical)

Response Time

< 300 ms (to 90% of final value, typical)

Update Rate

4 updates per second (typical)

General Specifications


Power Supply

Loop-Powered.​ No separate power terminals. Device is powered by the 4-20mA input signal.

Power Consumption

< 3.5V drop at 20mA (typical). Consumes power from the input loop.

Minimum Operating Voltage (Input Side)

Must have sufficient compliance voltage: V_min = 9.5V + (I_out * R_load).

Isolation

500V AC (Input to Output)

Common Mode Rejection

> 120 dB at 50/60 Hz

Operating Temperature

-20°C to +60°C (-4°F to +140°F)

Storage Temperature

-40°C to +85°C (-40°F to 185°F)

Relative Humidity

5-95% non-condensing

Connection Type

Screw clamp terminals

Wire Size

0.2-2.5 mm² (24-12 AWG)

Mounting

DIN rail 35mm (EN 60715)

Degree of Protection

IP20 (requires enclosure)

Dimensions (W × H × D)

12.5 × 100 × 115 mm

Weight

Approx. 90 g

Housing Material

Polycarbonate (UL 94 V-0)

LED Indicators

1 x Bicolor (Green/Red) for power and status. May flash for alarm.

Configuration

Fixed function (4-20mA in / 4-20mA out). No DIP switches.

Certifications

ATEX, IECEx, FM, CSA, NEPSI, SIL 2 capable, CE, RoHS

Note: Specifications are based on MTL 5000 series documentation. Always verify with the latest product datasheet.

Key Features

  • True Loop-Powered (2-Wire) Operation:​ Requires no separate power supply, powered directly from the 4-20mA input signal. Simplifies wiring and reduces costs.

  • Signal Boosting/Repeating:​ Regenerates a fresh, isolated 4-20mA output signal, capable of driving long cables or high loop loads.

  • Intrinsic Safety:​ Certified for Zone 1/21, providing isolation and protection for hazardous area transmitters.

  • Low Input Voltage Drop:​ Minimal burden on the input loop, preserving voltage for the field transmitter.

  • High Accuracy & Isolation:​ ±0.1% accuracy with 500V isolation between input and output.

  • Wide Output Load Capability:​ Can drive loads up to 600Ω, subject to sufficient input voltage.

  • Compact & Simple:​ No configuration required; simply wire into the loop.

  • Diagnostic Indication:​ Bicolor LED provides visual status (power, fault).

  • Global Hazardous Area Approvals:​ Suitable for installations worldwide.

Operating Principle & Voltage Compliance

The MTL 5049 is a 2-wire device inserted in series​ within the 4-20mA loop. It uses a small amount of power from the loop current to operate its internal electronics and generates a fresh, isolated output current.

Critical System Voltage Check:

For the loop to function, the Power Supply Voltage (Vs)​ must be greater than the sum of all voltage drops:

Vs > V_tx + V_5049 + (I_loop * R_load) + (I_loop * R_wire)

Where:

  • V_tx:​ Minimum operating voltage of the field transmitter (e.g., 12V).

  • V_5049:​ Voltage drop across the 5049 (approx. 3.5V at 20mA).

  • I_loop * R_load:​ Voltage drop across the receiver/load (e.g., 250Ω * 0.02A = 5V).

  • I_loop * R_wire:​ Voltage drop in the cable (usually small).

Example Calculation:

  • Transmitter (V_tx): 12V

  • MTL 5049 (V_5049): 3.5V

  • Load 250Ω at 20mA: 5.0V

  • Total Required:​ 20.5V

  • Minimum Supply (Vs):​ A 24V supply (21.6V min) is adequate. A 18V supply would fail.

Terminal Block Layout

The module has 4 screw terminals for loop connection.

Terminal

Designation

Connection

1

IN+ (Input Positive)

Connect to the positive​ side of the field transmitter​ or the source​ of the 4-20mA signal.

2

IN- (Input Negative)

Connect to the positive​ terminal of the output load​ (PLC/DCS input card). This forms the input loop.

3

OUT+ (Output Positive)

Connect to the positive​ side of the isolated output power supply​ (typically 24V DC).

4

OUT- (Output Negative)

Connect to the negative​ terminal of the output load​ (PLC/DCS input card) and to the negative​ of the output power supply. This forms the output loop.

Wiring Diagram

[Hazardous Area]        [Safe Area]              [Safe Area - Output Loop]
                       .----------------------.
Field                  |       MTL 5049       |   Output PSU
Xmtr(+) -------------- | IN+              OUT+| ----[24V DC +]---.
                       |                      |                  |
                       |                      |                  |
Field                  | IN-              OUT-| ---[Load: 250Ω]--+
Xmtr(-) ----[IS PSU -] |                      |                  |
                       '----------------------'                  |
                                                                  |
[IS PSU +] -------------------------------------------------------'

The field transmitter is powered by an IS power supply. The 5049 is powered by the current from this loop. The 5049's output is powered by a separate, standard 24V supply.

Entity Parameters (for Hazardous Area Loop Design)

Parameter

Symbol

Typical Value

Unit

Maximum Input Voltage (Ui)

Ui

30

V

Maximum Input Current (Ii)

Ii

30

mA

Maximum Input Power (Pi)

Pi

0.75

W

Maximum Internal Capacitance (Ci)

Ci

5.6

nF

Maximum Internal Inductance (Li)

Li

3.0

µH

Maximum Output Voltage (Uo)

Uo

30

V

Maximum Output Current (Io)

Io

30

mA

Maximum Output Power (Po)

Po

0.75

W

The connected field device (transmitter) in the hazardous area must be IS certified.

Typical Applications

  • Signal Boosting:​ Extending 4-20mA signal transmission distance by regenerating a fresh signal to overcome cable resistance.

  • Ground Loop Elimination:​ Isolating grounds between a field transmitter and control system to eliminate ground loop currents and noise.

  • Intrinsic Safety Interface:​ Providing IS isolation for a standard 4-20mA transmitter in a hazardous area.

  • Signal Re-transmission:​ Sending one transmitter signal to two separate receivers (when used with a signal splitter).

  • Legacy System Upgrades:​ Adding isolation to existing loops without rewiring for a separate power supply.

  • High Load Driving:​ Driving high-resistance loads (e.g., multiple indicators in series) that the original transmitter cannot drive alone.

Important Technical Notes

  1. Voltage Compliance is Critical:​ This is the most important design consideration. You must verify that the existing loop's power supply has sufficient voltage​ to power the field transmitter plus​ the MTL 5049 plus​ the load, at 20mA. Calculate: Vs(min) > V_tx(min) + 3.5V + (0.02 * R_load_total).

  2. Two Power Supplies:​ The input side​ of the loop requires an IS power supply for the field transmitter. The output side​ requires a separate, standard 24V DC power supply to power the output loop.

  3. Polarity Sensitive:​ The device is polarity sensitive. Ensure correct wiring as per the terminal designations.

  4. No Configuration:​ The unit is fixed as a 4-20mA input / 4-20mA output repeater. It cannot be configured for other ranges.

  5. LED Status:​ A green LED indicates normal operation. A red or flashing LED may indicate a fault (e.g., open circuit, insufficient voltage).

  6. Not a Isolated Barrier:​ It is an active isolator/repeater, not a passive Zener barrier. It conditions and regenerates the signal.

  7. Loop Disruption:​ Inserting the 5049 into an active loop will briefly break the circuit. Plan for this during installation.

  8. Output Power Supply:​ The output side requires its own 24V DC power supply. Do not connect the output to a passive input card expecting to source power.


Note: This data sheet provides general specifications for the MTL 5049 loop-powered isolator. For complete installation instructions, wiring diagrams, voltage compliance calculations, intrinsic safety guidelines, and certification details, consult the official MTL 5000 Series Technical Manual​ and the product-specific data sheet. Always perform the voltage compliance calculation before installation.

MTL 5049 Active Isolator | Loop-Powered, 4-20mA in/out, IS, DIN Rail, ATEX/IECEx/FM 0

About ACH

Founded in 2012, ACH is a top-tier distributor of industrial automation products, supplying genuine devices from leading brands like ABB, P+F, E&H, AB, MTL and EMERSON to emerging markets worldwide. Our mission is to provide 100% Genuine products at the most competitive prices, helping customers reduce costs and strengthen their market position.

MTL 5049 Active Isolator | Loop-Powered, 4-20mA in/out, IS, DIN Rail, ATEX/IECEx/FM 1
Frequently Ask & Questions
Are preferential prices available?

Long-term brand partners can get competitive product prices. At the same time, ACH controls the profit per order to 5%, providing the most competitive prices.

Are the Products Genuine OEM Units?

Yes, all products from ACH are certified genuine OEM units. We acquire our inventory through official OEM channels and trusted third-party suppliers, ensuring every item is authentic and reliable.

How will you arrange shipment?

We'll handle the shipping for you. Through our partnerships, we can secure competitive rates with major carriers like FedEx, DHL, TNT, and UPS, ensuring a smooth and cost-effective delivery.

What is the warranty of goods?

One-year Warranty.

How long is the logistics cycle of the product?

Products are divided into spot and futures, and the delivery period of different brands of products is also different. For details, please contact the ACH business manager.

Contact Details
Achievers Automation Limited

Contact Person: sales2

Send your inquiry directly to us