logo
100% genuine products & Actual product photos
Home
Products
Videos
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
News
Home ProductsWAGO Connectors

Phoenix Contact MINI MCR-2-UNI-UI-2UI | 2-Ch, Transducer, 0-10V/0-20mA, 2UI, 24V DC Specs

I'm Online Chat Now
Certification
china Achievers Automation Limited certification
china Achievers Automation Limited certification
"ACH has proven to be a reliable partner. Their products are genuine and high-quality, with competitive prices and on-time delivery. We trust them as our long-term supplier in automation."

—— Mohammed Al-Farsi, Procurement

"For us, cost efficiency and authenticity are key. ACH helps reduce expenses while ensuring reliable quality and timely supply, making them a strong partner in our operations."

—— Procurement Manager

"For us, cost efficiency and authenticity are key. ACH helps reduce expenses while ensuring reliable quality and timely supply, making them a strong partner in our operations."

—— Supply Chain Director

"ACH offers quick response, flexible solutions, and fair pricing. The products are always genuine and reliable, and their friendly support makes cooperation smooth."

—— Operations Manager

"ACH provides genuine products with stable quality and fair pricing. Their fast response and reliable delivery give us confidence to continue working with them."

—— Engineering Manager

"We value ACH for their consistent quality and competitive pricing. Deliveries are always reliable, and their professional support makes procurement much easier for our team."

—— Procurement Head

Phoenix Contact MINI MCR-2-UNI-UI-2UI | 2-Ch, Transducer, 0-10V/0-20mA, 2UI, 24V DC Specs

Phoenix Contact MINI MCR-2-UNI-UI-2UI | 2-Ch, Transducer, 0-10V/0-20mA, 2UI, 24V DC Specs

Large Image :  Phoenix Contact MINI MCR-2-UNI-UI-2UI | 2-Ch, Transducer, 0-10V/0-20mA, 2UI, 24V DC Specs Get Best Price

Product Details:
Place of Origin: DE
Brand Name: PHOENIX CONTACT
Certification: ATEX
Model Number: MINI MCR-2-UNI-UI-2UI
Document: ACH-AB-P+F-E+H-IFM-ASCO-YOK...WA.pdf
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: carton
Delivery Time: Negotiable
Payment Terms: T/T,XT,ALIPAY
Supply Ability: 100pcs per month
Detailed Product Description
Power Supply: 12-30 V DC (Two-wire) Ambient Temperature: -40°C To 80°C (-40°F To 176°F)
Electrical Rating: General Purpose, Explosion-proof, Intrinsic Safety (depends On Certification) Certifications: Standard Models Include ATEX, IECEx, SIL 2 (consult Manual For Specific Ratings)
Highlight:

Phoenix Contact MINI MCR transducer 24V DC

,

2-channel signal transducer 0-10V 0-20mA

,

MINI MCR-2-UNI-UI-2UI transducer with warranty

Phoenix Contact MINI MCR-2-UNI-UI-2UI | 2-Ch, Transducer, 0-10V/0-20mA, 2UI, 24V DC Specs

Phoenix Contact MINI MCR-2-UNI-UI-2UI signal conditioner specifications. 2-channel, universal input, 2-wire transmitter, 0-10V/0-20mA, 24V DC, DIN rail. For sensor isolation.


Product Overview

The Phoenix Contact MINI MCR-2-UNI-UI-2UI​ is a two-channel signal conditioner and isolating transmitter​ designed for industrial measurement and control applications. This module accepts universal analog inputs​ (voltage or current) and provides two-wire transmitter supply (2UI)​ for connected sensors. The module operates on 24V DC, provides galvanic isolation​ between input and output, and is mounted on DIN rail. The "MINI MCR-2-UNI-UI-2UI" designation specifies a 2-channel universal input conditioner with 2-wire transmitter supply. This device protects control systems from interference and provides signal conversion for sensors in harsh industrial environments.

Technical Specifications

Parameter

Specification

Complete Ordering Code

MINI MCR-2-UNI-UI-2UI

Product Series

Phoenix Contact MINI MCR-SL Series

Product Type

2-Channel Signal Conditioner / Isolating Transmitter

Channels

2 (independent, galvanically isolated)

Input Type

Universal (switchable per channel): Voltage or Current

Input Ranges (Voltage)

0-10V, 0-5V, 0-1V, ±10V, ±5V, ±1V

Input Ranges (Current)

0-20mA, 4-20mA, 0-10mA, ±20mA

Input Impedance (Voltage)

> 1 MΩ

Input Impedance (Current)

Approx. 50 Ω

Output Type

Passive (2-wire transmitter supply - 2UI)

Output Supply

24V DC loop power for 2-wire transmitters

Output Current (per channel)

Up to 25 mA (for connected 2-wire transmitter)

Transmitter Supply Voltage

Approx. 20V (at 20 mA load)

Galvanic Isolation

1.5 kV AC (input to output, channel to channel)

Accuracy

±0.1% of full scale value (typical)

Linearity Error

< 0.05%

Temperature Coefficient

< 0.01%/K

Response Time

< 2 ms (typical)

Bandwidth

150 Hz (-3 dB)

Common Mode Rejection

> 120 dB at 50 Hz

Power Supply

24V DC (20.4-28.8V DC)

Power Consumption

Approx. 1.5 W (with both channels active)

Connection Type

Screw clamp (spring-cage)

Wire Size

0.08-2.5 mm² (28-12 AWG)

Mounting

DIN rail 35 mm (EN 60715)

Degree of Protection

IP20

Ambient Temperature

-20°C to +60°C (operation), -40°C to +85°C (storage)

Relative Humidity

20-95% (non-condensing)

Dimensions (W × H × D)

17.5 × 99 × 114 mm (6 x module width)

Weight

Approx. 120 g

Certifications

CE, cULus, ATEX, IECEx, DNV GL, RoHS, REACH

Note: Specifications are based on Phoenix Contact MINI MCR series documentation. The "2-UNI-UI-2UI" suffix indicates 2-channel universal input with 2-wire transmitter supply. Always verify with the specific product datasheet.

Ordering Code Decoding (MINI MCR-2-UNI-UI-2UI)

  • MINI MCR:​ Product series (Miniature Measuring, Controlling, Relaying)

  • 2:​ Number of channels (2 channels)

  • UNI:​ Universal input (voltage or current, selectable)

  • UI:​ Output type (Passive, 2-wire transmitter supply)

  • 2UI:​ Specific configuration (2-wire transmitter interface with supply)

Key Features

  • Dual-Channel Design:​ Two independent, galvanically isolated channels in compact housing

  • Universal Input:​ Each channel independently configurable for voltage or current input

  • 2-Wire Transmitter Supply:​ Provides loop power for passive 2-wire transmitters

  • High Accuracy:​ ±0.1% accuracy for precise measurement

  • Galvanic Isolation:​ 1.5 kV isolation between input, output, and power supply

  • Wide Input Ranges:​ Multiple voltage and current ranges selectable

  • High Density:​ Only 17.5 mm wide (6 modules per 105 mm DIN rail)

  • Easy Configuration:​ Range selection via DIP switches on the module

  • LED Indicators:​ Power and status LEDs for each channel

  • Screw Clamp Connection:​ Reliable spring-cage connection technology

  • Global Certifications:​ Approved for use in hazardous areas

Connection Configuration

Terminal

Channel 1

Channel 2

Power

1

Input +

-

-

2

Input -

-

-

3

Output +

-

-

4

Output -

-

-

5

-

Input +

-

6

-

Input -

-

7

-

Output +

-

8

-

Output -

-

9

-

-

24V DC +

10

-

-

0V / GND

Note: Actual terminal assignment may vary. Always consult the product manual for proper wiring.

Typical Applications

  • Process Control:​ Signal conditioning for temperature, pressure, level, and flow transmitters

  • PLC/DCS Interface:​ Isolation and conversion between field sensors and control systems

  • 2-Wire Transmitter Power:​ Power supply for passive 4-20mA transmitters

  • Measurement Systems:​ Signal conditioning for data acquisition systems

  • Motor Control:​ Current and voltage measurement for motor monitoring

  • Energy Management:​ Power and energy measurement signal conditioning

  • HVAC Systems:​ Sensor signal conditioning for building automation

  • Test and Measurement:​ Laboratory and test bench signal isolation

  • Any application requiring:​ Galvanic isolation, signal conversion, or 2-wire transmitter power

Important Technical Notes

  1. Power Supply:​ Requires 24V DC power (20.4-28.8V DC). Ensure adequate current capacity for all connected transmitters.

  2. Input Configuration:​ Set input type (voltage/current) and range using DIP switches on the module before applying power.

  3. 2-Wire Transmitter Connection:​ Connect the transmitter between output+ and output- terminals. The module supplies power to the transmitter through these terminals.

  4. Load Limitation:​ Each channel can supply up to 25 mA. Ensure the connected 2-wire transmitter's current consumption is within this limit.

  5. Isolation:​ Provides 1.5 kV isolation between input, output, and power supply. Maintain proper creepage and clearance distances in panel design.

  6. Wiring:​ Use twisted pair or shielded cable for analog signals. Ground the shield at one end only (typically at the controller end).

  7. Environmental Conditions:​ While rated for -20°C to +60°C, performance is optimized at room temperature. Derating may be required at temperature extremes.

  8. Certifications:​ The module carries ATEX/IECEx certifications for hazardous areas. Follow all installation requirements for certified applications.


Note: This data sheet provides general specifications for the Phoenix Contact MINI MCR-2-UNI-UI-2UI signal conditioner. For complete wiring diagrams, configuration settings, installation guidelines, and certification details, consult the official Phoenix Contact MINI MCR-SL Technical Documentation.

About ACH

Founded in 2012, ACH is a top-tier distributor of industrial automation products, supplying genuine devices from leading brands like ABB, P+F, E&H, AB, MTL and EMERSON to emerging markets worldwide. Our mission is to provide 100% Genuine products at the most competitive prices, helping customers reduce costs and strengthen their market position.

Phoenix Contact MINI MCR-2-UNI-UI-2UI | 2-Ch, Transducer, 0-10V/0-20mA, 2UI, 24V DC Specs 1
Frequently Ask & Questions
Are preferential prices available?

Long-term brand partners can get competitive product prices. At the same time, ACH controls the profit per order to 5%, providing the most competitive prices.

Are the Products Genuine OEM Units?

Yes, all products from ACH are certified genuine OEM units. We acquire our inventory through official OEM channels and trusted third-party suppliers, ensuring every item is authentic and reliable.

How will you arrange shipment?

We'll handle the shipping for you. Through our partnerships, we can secure competitive rates with major carriers like FedEx, DHL, TNT, and UPS, ensuring a smooth and cost-effective delivery.

What is the warranty of goods?

One-year Warranty.

How long is the logistics cycle of the product?

Products are divided into spot and futures, and the delivery period of different brands of products is also different. For details, please contact the ACH business manager.

Contact Details
Achievers Automation Limited

Contact Person: sales2

Send your inquiry directly to us